Spain: Renewable energy advisory firm Renovetec has conducted research into fires at a number of concentrating solar power (CSP) plants in Spain. According to the company, mineral wool used to line the piping containing the heat transfer fluid (HTF) in these plants' solar fields is to blame.

"On occasions the causes of the fires have been unclear," explains Santiago García Garrido, Technical Director of Renovetec. "The HTF has behaved differently to the specifications on its safety sheet".

Renovetec has published an article on its work which examines the relationship between the thermal insulation used to line heat transfer piping and the fires, after the company managed to reproduce the conditions leading to certain fires under laboratory conditions. The tests performed by Renovetec show that the thermal insulation can ignite at below 200°C, whereby there is a risk of spontaneous combustion even if there is no ignition spark or other ignition source.

"This explains some of the incidents at a number of CSP plants," says the company especially given that the ignition point of the HTF generally used in CSP plants (biphenyl and diphenyl oxide) is 615°C – a temperature which is highly unlikely to be reached anywhere on site.

Witnesses of some of the fires recall that the incidents arose when some of the HTF escaped from the piping installed in the solar field soaking the thermal insulation (which is normally mineral wool) covered by an aluminium jacket. On removing the aluminium jacket, the mineral wool occasionally ignited spontaneously. These fires started despite the technical specifications of the HTF manufactured by Dow Chemical and Solutia indicating that the fluid would not ignite.

The outcome of Renovetec's experiment to reproduce the conditions leading to the fires is conclusive: on certain occasions the point of spontaneous combustion is not as reflected in the safety sheets of these HTF, with the liquid igniting at temperatures below 203°C.

Published in Global Insulation News
Tagged under
  • Spain
  • Mineral Wool

Related items

  • Russia raises mineral wool imports in first quarter of 2025
  • Green Wave Organic launches new peat-based substrate to replace mineral wool
  • Mineral Insulation announces upcoming €20m Miercurea-Ciuc mineral wool plant
  • TechnoNICOL to build new stone wool plant in Rostov
  • BBVA to finance residential renovations
Global Gypsum Monthly Sign up
Global Insulation LinkedIn
Global Insulation X
Acquisition appointment Belgium China CO2 Denmark France Germany Glass Wool government Insulation Ireland Johns Manville Kingspan Knauf Knauf Insulation Mineral Wool Owens Corning Plant Polyurethane Product Results Rockwool Russia SaintGobain Sustainability TechnoNICOL UK Upgrade US
« May 2025 »
Mon Tue Wed Thu Fri Sat Sun
      1 2 3 4
5 6 7 8 9 10 11
12 13 14 15 16 17 18
19 20 21 22 23 24 25
26 27 28 29 30 31  
  • Home
  • News
  • Conferences
  • Directory
  • Magazine
  • Knowledge Base
  • Awards
  • My details
  • Advertise
  • About
  • Privacy & Cookie Policy
  • Contact
  • Magazine >>
  • Introduction
  • Back issues
  • Articles
  • Conferences >>
  • Global CemBoards
  • Global CemCCUS
  • Global CemFuels
  • Global Concrete
  • Global FutureCem
  • Global Gypsum
  • Global GypSupply
  • Global Insulation
  • Global Slag
  • Websites >>
  • Global Cement
  • Global Gypsum
  • Global Slag
  • Global CemFuels
  • Global Concrete
  • Pro Global Media
  • PRoIDS Online

© 2025 Pro Global Media Ltd. All rights reserved